| PARAMETER | SPECIFICATION |
|---|
| Input Voltage | 230V ±10% A C, 50Hz, single phase |
| No. of Output | 2 |
| Output Voltage1 | | Output Voltage2 |
| | 125kV | 160kV | 220kV |
|---|
| 0 to +62.5kV DC | 0 to +80kV DC | 0 to +110kV DC | | 0 to +62.5kV DC | 0 to +80kV DC | 0 to +110kV DC |
|
| Output Current | 0 to 5mA |
Filament Voltage and Current As per tube selection by OEM | As per tube selection by OEM |
| Polarity | Positive and negative |
| Line Regulation | <0.1% for 10% variation in input voltage |
| Load Regulation | <0.5% for 10% load variation (tube current) |
| Mode of Operation | Constant voltage-constant current (x-ray anode current) |
| Protections | Overload, short-circuit and arc |
| Topology | SMPS |
| Cable and Connectors | To be supplied by the OEM |
| | MS tank (550mmx329mmx246mm) | | 19” Rack (440mmx458mmx142mm) |
|